Trim - Roof Laps
(Revised: 07/31/19)
SSR:
Purlin Upper
Panel Adjust = -7" Lower
Panel Adjust = +11" |
Bar
Joist Upper
Panel Adjust = -7" Lower
Panel Adjust = +11" |
WideBay Upper
Panel Adjust = -7" Lower
Panel Adjust = +11" |
SLR:
Purlin Notch with Punch Upper
Panel Adjust = -3/16" Lower
Panel Adjust = +6 3/16" |
Bar
Joist Not Defined by PE Notch with Punch Upper
Panel Adjust = -3/16" Lower
Panel Adjust = +6 3/16" |
Purlins
or Bar Joist (West
Coast Lap) Square
(Field Notch) Upper
Panel Adjust = -5" Lower
Panel Adjust = +10" |
Panel Rib Roofs:
Purlin Upper
Panel Adjust = 0" Lower
Panel Adjust = +4" |
|
|
Staggered Lap (SSR & SLR):
When the maximum panel
length is exceeded, a staggered panel lap is required: The
laps should be locate using the longest default panels possible from the Low
Eave The
shortest panels near the High Eave or Ridge should span a minimum of 3
secondary members Locate
all laps at secondary members that are continuous from BL to BL (Rake) The
maximum stagger = 5’-0” Attempt
to avoid staggered laps that straddle inside corners at an “L”
shape building. The
1st Panel in the set at the Low Eave is Long The
1st Panel in the set at the Ridge / High Eave is Short Any
Panels at Intermediate sets are detailed the same lengths but staggered.
|
Standard Lap (Panel Rib):
When the maximum panel
length is exceeded, a panel lap is required: The
laps should be locate using the longest default panels possible from the Low
Eave The
shortest panels near the High Eave or Ridge should span a minimum of 3
secondary members Locate
all laps at secondary members that are continuous from BL to BL (Rake) |