Trim - Roof Laps

(Revised: 07/31/19)

SSR:

Purlin

Upper Panel Adjust = -7"

Lower Panel Adjust = +11"

 

Bar Joist

Upper Panel Adjust = -7"

Lower Panel Adjust = +11"

WideBay

Upper Panel Adjust = -7"

Lower Panel Adjust = +11"

SLR:

Purlin

Notch with Punch

Upper Panel Adjust = -3/16"

Lower Panel Adjust = +6 3/16"

 

 

Bar Joist

Not Defined by PE

Notch with Punch

Upper Panel Adjust = -3/16"

Lower Panel Adjust = +6 3/16"

 

Purlins or Bar Joist

(West Coast Lap)

Square (Field Notch)

Upper Panel Adjust = -5"

Lower Panel Adjust = +10"

 

Panel Rib Roofs:

Purlin

Upper Panel Adjust = 0"

Lower Panel Adjust = +4"

 

 

 

Staggered Lap (SSR & SLR):

When the maximum panel length is exceeded, a staggered panel lap is required:

The laps should be locate using the longest default panels possible from the Low Eave

The shortest panels near the High Eave or Ridge should span a minimum of 3 secondary members

Locate all laps at secondary members that are continuous from BL to BL (Rake)

The maximum stagger = 5’-0ā€

Attempt to avoid staggered laps that straddle inside corners at an ā€œLā€ shape building.

 

The 1st Panel in the set at the Low Eave is Long

The 1st Panel in the set at the Ridge / High Eave is Short

Any Panels at Intermediate sets are detailed the same lengths but staggered.

 

Standard Lap (Panel Rib):

When the maximum panel length is exceeded, a panel lap is required:

The laps should be locate using the longest default panels possible from the Low Eave

The shortest panels near the High Eave or Ridge should span a minimum of 3 secondary members

Locate all laps at secondary members that are continuous from BL to BL (Rake)